Home > ELECTRICAL > ROUGH ELECTRICAL > FUSES & BREAKERS > CIRCUIT BREAKERS - ARC FAULT
Sort By:
1 2 3 4
MES Q120AFC Arc Fault Combination Miniature Circuit Breaker
Siemens QA120AFC Circuit Breaker, AFCI, Combination, 20 A, 1 -Pole, 120/240 V, Fixed Trip, Plug Mounting
Suggested Retail: $67.99

Plug-in, combination type CAFCI circuit breaker, complies with the requirements for both branch/feeder and outlet circuit CAFCIs. Required on January 1, 2008 by 2005 NEC, combination type CAFCI circuit breakers must be placed on bedroom power and lighting circuits. Protects downstream branch circuit wiring and cord sets and power supply cords. Provides ARC fault, overload and short circuit protection. UL listed. Protects against worn electrical insulation or damaged wire, misapplied or damaged plug-in appliances and equipment and loose electrical connections. 2 LEDs appear for 5 secs each time the CAFCI is turned on, up to 30 days after the last trip to indicate last known trip condition. One LED means arcing fault. Two LEDs means arcing fault to ground. 10 kA interrupting rating. UL listed, 120 VAC. Wire range 14 to 8 AWG. 1 in space, 120 V. more info
MES Q115AFC Arc Fault Combination Miniature Circuit Breaker
Siemens QA115AFC Circuit Breaker, AFCI, Combination, 15 A, 1 -Pole, 120/240 V, Fixed Trip, Plug Mounting, Black
Suggested Retail: $69.99

Plug-in, combination type CAFCI circuit breaker, complies with the requirements for both branch/feeder and outlet circuit CAFCIs. Required on January 1, 2008 by 2005 NEC, combination type CAFCI circuit breakers must be placed on bedroom power and lighting circuits. Protects downstream branch circuit wiring and cord sets and power supply cords. Provides ARC fault, overload and short circuit protection. UL listed. Protects against worn electrical insulation or damaged wire, misapplied or damaged plug-in appliances and equipment and loose electrical connections. 2 LEDs appear for 5 secs each time the CAFCI is turned on, up to 30 days after the last trip to indicate last known trip condition. One LED means arcing fault. Two LEDs means arcing fault to ground. 10 kA interrupting rating. UL listed, 120 VAC. Wire range 14 to 8 AWG. 1 in space, 120 V. more info
HomeLine HOM120CAFIC Arc Fault Combination Circuit Breaker
Square D HOM120CAFIC Circuit Breaker, AFCI, Combination, 20 A, 1 -Pole, 120 V, Fixed Trip, Plug Mounting
Suggested Retail: $69.99

Single-pole 1 in combination CAFCI circuit breaker is designed for arc-fault, overload and short-circuit protection of an electrical system. Designed to detect arcs that are caused by damaged, aged or improperly used wires or cords and to disconnect the power. With Time-Saver Diagnostics, advanced trip indication technology, identifying the type of fault that last occurred. White push to test button. 10 kA interrupting rating. Rated for 120 VAC. Meets Canadian Electrical code. Carded. more info
HomeLine HOM115CAFIC Arc Fault Combination Circuit Breaker
Square D HOM115CAFIC Circuit Breaker, AFCI, Combination, 15 A, 1 -Pole, 120 V, Fixed Trip, Plug Mounting
Suggested Retail: $69.99

Single-pole 1 in combination CAFCI circuit breaker is designed for arc-fault, overload and short-circuit protection of an electrical system. Designed to detect arcs that are caused by damaged, aged or improperly used wires or cords and to disconnect the power. With Time-Saver Diagnostics, advanced trip indication technology, identifying the type of fault that last occurred. White push to test button. 10 kA interrupting rating. Rated for 120 VAC. Meets Canadian Electrical code. Carded. more info
GE THQL Arc Fault Combination Circuit Breaker
GE THQL1115AFP2 Circuit Breaker, AFCI, 15 A, 2-Pole, 120/240 V, Plug
Suggested Retail: $69.99

Provides ARC fault, parallel, ground, Series, overload and short circuit protection. Required for bedroom receptacles effective January 1, 2002. Plug in design with color-coded screws and dual function test button. 120/240 V. 1 in space per breaker. more info
GE THQL Arc Fault Combination Circuit Breaker
GE THQL1120AFP2 Circuit Breaker, AFCI, 20 A, 2-Pole, 120/240 V, Plug
Suggested Retail: $69.99

Provides ARC fault, parallel, ground, Series, overload and short circuit protection. Required for bedroom receptacles effective January 1, 2002. Plug in design with color-coded screws and dual function test button. 120/240 V. 1 in space per breaker. more info
HomeLine HOM115PCAFIC CAFCI Miniature Standard Circuit Breaker
Square D HOM115PCAFIC Circuit Breaker, CAFCI, Mini, 15 A, 1 -Pole, 120 V, Plug Mounting
Suggested Retail: $69.99

Continuously monitors the circuit and quickly turns off the power (trips) when a dangerous condition is detected. Equipped with a diagnostic feature known as time-saver diagnostics which indicates the type of fault that last occurred on the circuit. more info
HomeLine HOM120PCAFIC CAFCI Miniature Standard Circuit Breaker
Square D HOM120PCAFIC Circuit Breaker, CAFCI, Mini, 20 A, 1 -Pole, 120 V, Plug Mounting
Suggested Retail: $69.99

Continuously monitors the circuit and quickly turns off the power (trips) when a dangerous condition is detected. Equipped with a diagnostic feature known as time-saver diagnostics which indicates the type of fault that last occurred on the circuit. more info
BREAKER CIRC ARCFAULT 120V 15A
Siemens QA115AFCN Circuit Breaker, AFCI, Combination, Low Voltage, 15 A, 1 -Pole, 120 V, Plug Mounting
Suggested Retail: $69.99

Siemens Circuit Breaker, AFCI, Combination, Low Voltage, 120 V, 15 A, 1 Pole, 10 kA Interrupt, QAF2N Frame, Lug Terminal, Plug Mounting, Suitable for: Plug-On Neutral Load Center more info
BREAKER CIRC ARCFAULT 120V 20A
Siemens QA120AFCN Circuit Breaker, AFCI, Combination, Low Voltage, 20 A, 1 -Pole, 120 V, Plug Mounting
Suggested Retail: $69.99

Siemens Circuit Breaker, AFCI, Combination, Low Voltage, 120 V, 20 A, 1 Pole, 10 kA Interrupt, QAF2N Frame, Lug Terminal, Plug Mounting, Suitable for: Plug-On Neutral Load Center more info
   
 
1 2 3 4